Contact edge

Safety contact strips on door edges protect people and goods

Characteristics

  • As soon as the contact strip is actuated, the gate either stops immediately or opens again
  • Consists of an aluminum C-support profile and a rubber profile with built-in switching element
  • If 2 contact strips are used on the door, one of them must be a “pass-through strip” without end resistance
  • An electronic evaluation device monitors whether the switching contact is closed or the safety circuit is interrupted, i.e. the contact strip is actuated
  • The power supply to the contact edge is provided by a spiral wire or a power supply rail with helical cable system WLS, which is installed either on top of the door or in the vicinity of the door rail
  • For the electrical connection of the spiral cable, two junction boxes must be installed: one fixed to the wall and one on the door
  • Contact type: Normally open contact (NO)

Product details

Technical data

MaterialTPE
Protection classIP 67
Switching angle2x 45°
Operating temperature-10°C to +50°C
Wire cross-section2 x 0,34 mm2
Electrical capacity24 V 10 mA

Dimensions

All dimensions in mm

Evaluation device

Contact type

  • Normally open contact (NO)

Technical data

Supply voltage230 VAC ± 10%, 50Hz, 24 AC/DC ± 10%
Power consumption3,5 VA/230 V, 1,5 W 24 VDC, 1,2 VA 24 VAC
Protection classIP 20
Operating temperature-20°C to +55°C

Dimensions

All dimensions in mm

WLS helical cable system

Characteristics

  • The power is transmitted via the WLS helical cable system
  • Consists of the WLS profile tube and an abrasion-resistant and extremely stable helical cable with carriage matched to the profile
  • Total length (RL) is calculated as follows: RL = FW + SL + 100 mm

Technical data

Core count / cross section4x 0,14 mm2
Supply voltagemax. 48 V AC/DC
Operating temperature-20°C to +80°C
Travel speed40 m/min
Travel distance1,5 m - 23,5 m
Length2,0 m - 26,0 m
in fixed dimensions: 2, 3, 4 and 6 m
Guide profileAluminum, anodized, torsion resistant

Dimensions

All dimensions in mm

Max. travel distance FW (m)Profile tube length RL (m)Space required SL (m)
1,520,3
1,6 - 2,530,4
2,6 - 3,540,4
3,6 - 4,35 (2 + 3)0,6
4,4 - 5,360,6
5,4 - 6,17 (3 + 4)0,8
6,2 - 7,18 (4 + 4)0,8
7,2 - 8,09 (3 + 6)0,9
8,1 - 9,010 (4 +6)0,9

Spiral cable

Technical data

Spiral lengthup to 3000 mm
Extended lengthup to 4 times spiral length
Conductorplain copper, fine stranded according to VDE 0295 class 5
Nominal voltage300/500 V
Test voltagecore/core 2000 V
Operating temperature-5°C to +80°C
Cable cross section2 x 0,75 mm2

Order information

Order Information

DescriptionPart No.
Contact edge SKL 35-55, end strip incl. 2,5 m connecting cable and aluminium profile700785
Safety contact edge SKL 35-55, transit strip incl. 2,5 m connecting cable and aluminium profile700786
Evaluation device for contact edge SKL 35-55, 230V / 24 V AC/DC, one channel700788
CI-K casing, not ex-proof040585
Conductor rail helical cable system WLS, length: XXX700794
Spiral cable (2-core), extension length 3,0 m incl. terminal box with glands700798
Spiral cable (2-core), extension length 6,0 m incl. terminal box with glands700799
Terminal box with glands700789