Contact edge
Safety contact strips on door edges protect people and goods
Characteristics
- As soon as the contact strip is actuated, the gate either stops immediately or opens again
- Consists of an aluminum C-support profile and a rubber profile with built-in switching element
- If 2 contact strips are used on the door, one of them must be a “pass-through strip” without end resistance
- An electronic evaluation device monitors whether the switching contact is closed or the safety circuit is interrupted, i.e. the contact strip is actuated
- The power supply to the contact edge is provided by a spiral wire or a power supply rail with helical cable system WLS, which is installed either on top of the door or in the vicinity of the door rail
- For the electrical connection of the spiral cable, two junction boxes must be installed: one fixed to the wall and one on the door
- Contact type: Normally open contact (NO)
Product details
Technical data
Material | TPE |
Protection class | IP 67 |
Switching angle | 2x 45° |
Operating temperature | -10°C to +50°C |
Wire cross-section | 2 x 0,34 mm2 |
Electrical capacity | 24 V 10 mA |
Evaluation device
Contact type
- Normally open contact (NO)
Technical data
Supply voltage | 230 VAC ± 10%, 50Hz, 24 AC/DC ± 10% |
Power consumption | 3,5 VA/230 V, 1,5 W 24 VDC, 1,2 VA 24 VAC |
Protection class | IP 20 |
Operating temperature | -20°C to +55°C |
Dimensions
All dimensions in mm
WLS helical cable system
Characteristics
- The power is transmitted via the WLS helical cable system
- Consists of the WLS profile tube and an abrasion-resistant and extremely stable helical cable with carriage matched to the profile
- Total length (RL) is calculated as follows: RL = FW + SL + 100 mm
Technical data
Core count / cross section | 4x 0,14 mm2 |
Supply voltage | max. 48 V AC/DC |
Operating temperature | -20°C to +80°C |
Travel speed | 40 m/min |
Travel distance | 1,5 m - 23,5 m |
Length | 2,0 m - 26,0 m in fixed dimensions: 2, 3, 4 and 6 m |
Guide profile | Aluminum, anodized, torsion resistant |
Dimensions
All dimensions in mm
Max. travel distance FW (m) | Profile tube length RL (m) | Space required SL (m) |
---|---|---|
1,5 | 2 | 0,3 |
1,6 - 2,5 | 3 | 0,4 |
2,6 - 3,5 | 4 | 0,4 |
3,6 - 4,3 | 5 (2 + 3) | 0,6 |
4,4 - 5,3 | 6 | 0,6 |
5,4 - 6,1 | 7 (3 + 4) | 0,8 |
6,2 - 7,1 | 8 (4 + 4) | 0,8 |
7,2 - 8,0 | 9 (3 + 6) | 0,9 |
8,1 - 9,0 | 10 (4 +6) | 0,9 |
Spiral cable
Technical data
Spiral length | up to 3000 mm |
Extended length | up to 4 times spiral length |
Conductor | plain copper, fine stranded according to VDE 0295 class 5 |
Nominal voltage | 300/500 V |
Test voltage | core/core 2000 V |
Operating temperature | -5°C to +80°C |
Cable cross section | 2 x 0,75 mm2 |
Order information
Order Information
Description | Part No. |
---|---|
Contact edge SKL 35-55, end strip incl. 2,5 m connecting cable and aluminium profile | 700785 |
Safety contact edge SKL 35-55, transit strip incl. 2,5 m connecting cable and aluminium profile | 700786 |
Evaluation device for contact edge SKL 35-55, 230V / 24 V AC/DC, one channel | 700788 |
CI-K casing, not ex-proof | 040585 |
Conductor rail helical cable system WLS, length: XXX | 700794 |
Spiral cable (2-core), extension length 3,0 m incl. terminal box with glands | 700798 |
Spiral cable (2-core), extension length 6,0 m incl. terminal box with glands | 700799 |
Terminal box with glands | 700789 |
Downloads
File name | Type |
---|---|
Documents | |
Catalog Safety & operating devices | |
STEP Drawings | |
STEP Contact edge, 700785, 700786 | stp |
STEP Aluminum rail for safety edge, 700785, 700786 | stp |
STEP Evaluation device, 700788 | stp |