Distribution box VK3

For the peripheral interlock control system

Characteristics

The simple wiring of all the components in the peripheral interlock control system is based on the distribution box(es) VK3.

If there are several distribution boxes, these are connected by a pluggable control cable and power cable each.

The control terminals of the corresponding doors are then connected to the distribution box by also pluggable connection cables.

Product details

Technical data

Materialhot-dip galvanized sheet steel
IP ratingIP 20
Top hat railtype TS35/7.5 according to EN 60715
PlacingThe maximum distance (length of cable) between a distribution box and a control terminal is 15 m.

Amount

Number of required distribution boxes

Each distribution box disposes of 4 sockets each for the control and the power cables. These are used to connect the control terminals and, if needed, several distribution boxes.

Example 1: Interlock system with 4 adjoining doors

Here one distribution box is sufficient to connect all doors directly.

Interlock Control System 4 Doors

Example 2: Interlock system with 8 doors

To the distribution box 1 can be connected 3 doors. The 4th sockets are needed for the connection cables to the 2nd distribution box.
To the 2nd distribution box can be connected 2 doors as 1 socket each is needed for the incoming and one each for the outgoing cables. To the 3rd distribution box there can again be connected 3 doors as only one socket each is needed for the incoming connection cables.

Interlock Control System 8 Doors

Functions

Global emergency-open

If required, the function global emergency-open (when pressing one emergency-open switch, all doors are unlocked) is adjusted in the distribution box. To achieve this, there is fitted an additional relay (part no. 710921) with pluggable connection cable in only one distribution box of the interlock control system. It is simply clipped to the standard top hat rail in the distribution box. For the connector of this connection cable the additional socket X6 is reserved.

ATTENTION: When choosing the global emergency-open, the 6 core power cable has to be used!

Additional adjustable functions

The X5 terminal strip can be used for special functions. For example, to additionally lock any doors by a “privacy switch” (changing rooms) and to connect an external time control unit with display. The delivery of the distribution box includes a connector for the X5 terminal strip which facilitates an easy connection of these devices.

Dimensions

All dimensions in mm

Verteilerkasten dezentrale Schleusensteuerung Maße

The strain relief of the incoming and outgoing cables is achieved by fixing the cables with tie wraps to the two cable support brackets. The cable inlets are sealed dust proof by cellular material.

For fixing 4 borings of Ø 5.4 mm are provided in the casing of the distribution boxes.

Order information

Order Information

DescriptionPart No.
Kit of 4 pluggable 6 core screw terminals for the distribution box VK 3710923
Additional relay for global emergency-open, retrofittable, for distribution box VK3 of DICTATOR interlock control system, with pluggable connection cable710921
Distribution box VK3 for DICTATOR interlock control system, for max. 4 doors, with top hat rail and connector for the X5 terminal strip710922